Guangzhou Hedsom Building Material Co., Ltd

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsRaised Access Floor Tiles

60X60/50X50 hpl covering Raised Floor Panels High Strength Data Center Server Room access Floor

60X60/50X50 hpl covering Raised Floor Panels High Strength Data Center Server Room access Floor

  • 60X60/50X50 hpl covering Raised Floor Panels High Strength Data Center Server Room access Floor
  • 60X60/50X50 hpl covering Raised Floor Panels High Strength Data Center Server Room access Floor
  • 60X60/50X50 hpl covering Raised Floor Panels High Strength Data Center Server Room access Floor
  • 60X60/50X50 hpl covering Raised Floor Panels High Strength Data Center Server Room access Floor
  • 60X60/50X50 hpl covering Raised Floor Panels High Strength Data Center Server Room access Floor
  • 60X60/50X50 hpl covering Raised Floor Panels High Strength Data Center Server Room access Floor
60X60/50X50 hpl covering Raised Floor Panels High Strength Data Center Server Room access Floor
Product Details:
Brand Name: PARETE
Certification: ISO, CISCA, SGS
Model Number: C3
Payment & Shipping Terms:
Minimum Order Quantity: 100
Price: negotiated price
Delivery Time: 1 weeks
Payment Terms: L/C, T/T, Western Union, MoneyGram
Supply Ability: 30000 square meters per month
Contact Now
Detailed Product Description
Material: Full Of Cement Core Finish: HPL
Color: Multi
High Light:

raised floor tiles

,

raised floor panels

Steel raised access floor with HPL covering

 

Product discription

 Antistatic Access Floor is made of good quality cold-rolled steel sheet with foaming cement fully filled. The  bottom is high quality deep stretch coil steel plate. The top is  cold rolled hard plate. The top steel plate and bottom steel plate are spot-welded to form a high quality shell. The shell is treated by phosphate and painted with epoxy powder coating. Then foaming cement will be filled into the shell. After curing, the structure will be stable and strong to support the designed loading capacity . The access floor panel has high strength and high durability.

 

Project Cases

 

11.png

            Some of the Project References List

Project name

Model/Panel Size

(mm)

Thickness Core Material Area(m*m) Application Field
Guangzhou Baiyun Airport FS1000 600*600 35mm Steel infill with cement 13000 Office,Control Center,Server Room
Guangzhou International Financial Center FS1000 600*600 35mm Steel infill with cement 22500 Office
Guangzhou Opera House FS1000 600*600 35mm Steel infill with cement 3700 Office,Control Center
Guangzhou TaiKoo Hui FS662 600*600 30mm Calcium sulphate 3000 Office
Guangzhou Vanlas Fort Hotel Office FS662 600*600 33mm Steel infill with cement 20000 Office
Guangzhou media port FS1000 600*600 35mm Steel infill with cement 12500 Office,Control Center,Server Room
Guangzhou Tianhe No.2 super computer FS1250 600*600 35mm Steel infill with cement 7820 Server Room
Guangzhou Nansha Toyota FS1000 600*600 35mm Steel infill with cement 3900 Office,Control Center,Server Room
Guangzhou Times Property E-park FS662 600*600 28mm Steel infill with cement 55000 Office
Guangzhou Panyu China Mobile FS1250 600*600 32mm Calcium sulphate 3200 Server Room
Guangzhou Modern Plaza FS662 600*600 33mm Steel infill with cement 20000 Office
Guangzhou Fedex Transition Center FS1000 600*600 33mm Steel infill with cement 4800 Office,Control Center,Data Center
Guangzhou tax plaza FS1000 600*600 35mm Steel infill with cement 12900 Data Center
Guangzhou Museum FS1000 600*600 35mm Steel infill with cement 2400 Data Center
Guangzhou C&F Science Plaza FS662 600*600 35mm Steel infill with cement 13800 Office
Guangzhou Baiyun Conference Center FS1000 600*600 35mm Steel infill with cement 3500 Office,Control Center
Shenzhen Kade No.1 Park FS662 500*500 28mm Steel infill with cement 15000 Office
Shenzhen Pingan Plaza FS662 600*600 35mm Steel infill with cement 2000 Office,Data Center
Shenzhen Baili Plaza FS662 600*600 33mm Steel infill with cement 30000 Office
Shenzhen Qianhai Times Plaza FS662 500*500 28mm Steel infill with cement 10000 Office
Shenzhen New Huafu FS662 600*600 35mm Steel infill with cement 10000 Office
China Mobile (Guangdong branch) FS1250 600*600 35mm Calcium sulphate 10000 Server Room
China Mobile (GuangXi branch) FS1000 600*600 35mm Steel infill with cement 30000 Server Room
China Mobile (Tanshan branch) FS1250 600*600 35mm Calcium sulphate 800 Server Room
China Mobile (Sichuan branch) FS1000 600*600 35mm Steel infill with cement 700 Server Room
China Mobile (Quanzhou branch) FS1000 600*600 35mm Steel infill with cement 1600 Server Room
China Mobile (NingXia branch) FS1000 600*600 35mm Steel infill with cement 1200 Server Room
China Mobile (Hebei branch) FS1000 600*600 35mm Steel infill with cement 1000 Server Room
China Mobile (Liaoning branch) FS1000 600*600 32mm Steel infill with cement 25000 Server Room
China Mobile (Jiangxi branch) FS1250 600*600 35mm Calcium sulphate 1200 Server Room
China Mobile (Hunan branch) FS1250 600*600 32mm Calcium sulphate 26700 Server Room
China Mobile (Guizhou branch) FS1000 600*600 35mm Steel infill with cement 1200 Server Room
China Mobile (South Center in Guangzhou) FS1000 600*600 35mm Steel infill with cement 13043 Server Room
Huizhou Kaisa Commercial building FS662 600*600 35mm Steel infill with cement 10000 Office
Huizhou TSINGHUA TONFANG FS662 600*600 35mm Steel infill with cement 30000 Office

 

 

01-welding.jpg

 

Product advantages:

 1. Made of steel plate, high mechanical strength, high loading capacity, good fire resistance.

2. Epoxy power painting on surface, matt and soft, wear resistant and anti-corrosion.

3. Covering is glued under high pressure.  Multiple choices and good decorated surface. Wear resistant and anti scratch, excellent electrical conductivity, anti pollution and easy cleaning.

4. High dimensional accuracy,  interchangeable, flexible assembly, easy maintenance.

5. Products can be upgraded or adjusted according to the loading requirements.

 

Technical data of steel anti-static access floor 

Size Thickness

Concentrated load

(deflection=2mm)

Ultimate

load

Uniform

load

Rolling load

Electrical

resistance

(mm) (mm) lb N kg N N/m2 N deflection Permanent deformation (Ω)
PRT-FS662 600×600 35 662 2950 301 8850 12500 2255 ≤2mm ≤0.5mm 106 - 1010
PRT-FS800 600×600 35 800 3550 363 10650 16500 2950 106 - 1010
PRT-FS1000 600×600 35 1000 4450 454 13350 23000 3560 106 - 1010
PRT-FS1250 600×600 35 1250 5560 567 16680 33000 4450 106 - 1010
PRT-FS1500 600×600 38 1500 6665 680 19995 39324 5560 106 - 1010
PRT-FS2000 600×600 38 2000 9000 910 31130 58000 8000 106 - 1010
CICAS or BS standard size panel Parete can provide the size 24’’ ×24’’ (610mm×610mm) access floor panel.
Floor covering HPL, PVC or Ceramic tile (Page 18-21)
Raised height Normally from 100mm to 1000mm, above 1000mm, it should be in special solution.
Electrical resistance It will be 104-106 When use the PVC coverings.

 

HPL covering

 

After using a variety of special paper phenolic, melamine, resin processing, high temperature and pressure made of thermosetting resin decorative laminates. It is not only bright color, bright and smooth, and has a wear-resistant, heat resistance, pollution, washable and permanent decorative features, the standard thickness of 0.8mm, 1.0mm, 1.2mm, 1.5mm, the thickness can development of user requirements.

High pressure melamine laminate is widely used in varies computer rooms and data centers. It is anti-static, anti-wear and free of pollution.  It is anti scratch and wear resistance. It is economical and easy glued on the surface of metal, calcium sulphate panel and wood core surface. So it is the most welcome floor covering.

 01-steel_hpl_covering

 

 

Floor Applications

Raised Floor applications area

 

Industry

areas

manufacture

Electronic factory, transformer substation, hydropower, oil tank, cement factory, motor industry etc.

financial

Bank, security, telecom, insurance

Commercial

Hotel, Shopping mall, intelligent office, logistic center

Government

School, tax bureau, police station, frontier inspection station, national defense center, industrial and commercial bureau, custom, national conference center etc.

Public facility

Hospital, military, highway, airport, TV station, radio and TV center

 

 

Computer room and data center

 

Supply the cooling air from the underfloor and return the air from top is the most common way of air conditioning system in large or medium scale data center or computer room. The cooling air from the air handling unit (AHU) will fast reach to the cabinet and equipment. The density of cooling air is larger than the hot air, so the cooling air will go down and the hot air will go up. When the hot air goes up, the cooling air will fill the space left by the hot air gone. Then it will be a circulation. This is a thermodynamic circulation. This circulation don’t like the horizontal flowing wind. It is a convective motion. It is helpful for the cooling of the equipment.

The anti-static perforated access floor provide a perfect solution to achieve this kind of air conditioning system. The perforated access floor will be raised to a designed height. The cooling air will be supplied under the access floor. There are steel and aluminum perforated access floor. The steel anti-static perforated access floor system will be in the page 8-9 and the aluminum will be in page 12-13 of this brochure.

 

Cleaning room

 

Cleaning room is a super clean environment.  It not only need to control the ventilation, filtration, temperature, humidity, pressure and ionization etc., but also need to control the materials and other parameters. The cleanliness of the cleaning room is decided by the aerosols’ quantities in the air. The unit of the aerosols is micrometer ( 10-6 meter, 0.000039 inch ).

It is very necessary to control the static charge generated in the cleaning room. Static may influence on the production.The automatic equipment may be failure for the electromagnetic interference of static charge. Electro static attraction (ESA) generated by static charge will reduce the particles attached on the surface. Static charge have close relation with the pollution on the surface of products and tools. So people pay more and more attention to ESA. For example, a 4 inch chip takes 1000v static charge. It will  cause 830000 lbf/Sq. in ESA intensity to a particle of 1 micrometer diameter. So the ESA on the static charge item is much higher than the gravity, air force and adhesive force. So conduct the static charge is very important for cleaning room. The anti-static access floor is one of the most important anti-static material in the cleaning room.

 

 

01-steel_hpl3

Computer room raised floor

 

 

01-steel_hpl6

Control Center access floor/ mornintoring room access floor

 

01-steel_hpl7

College teaching room access floor / computer room raised floor

 

01-steel_hpl2

UPS room raised floor

 

 

 

01-steel_hpl

Data center raised floor with insulation

 

01-steel_hpl4

Control center raised floor

 

 

More Information

alibaba contacts 

 

Contact Details
Guangzhou Hedsom Building Material Co., Ltd

Contact Person: winsom

Send your inquiry directly to us (0 / 3000)